TIME®2600: Coating thickness gauge for Fe and NFe with integrated printer
TIME®2600
Coating thickness measurement on ferrous and non-ferrous metals – with integrated printer
The TIME®2600 coating thickness gauge measures paints and coatings non-destructively using the magnetic induction method (non-magnetic coatings on iron and steel) and the eddy current method (non-conductive coatings on non-ferrous metals). Six different probe types are available for different applications.
The integrated printer outputs readings and statistics directly – suitable for laboratory and field use.
Features of the TIME®2600
- two measuring principles: magnetic induction (Fe) and eddy current (NFe)
- 6 probe types for different applications
- two working modes: DIRECT and BATCH, two measuring ways: CONTINUE and SINGLE
- statistics: mean, maximum, minimum, number of readings and standard deviation
- memory for 640 readings
- two calibration methods (zero and foil calibration)
- integrated printer for the statistical values
- adjustable limits with alarm
- low battery indication and error alarm
- backlight for the screen
- manual or automatic shutdown
- conforms to DIN, ISO, ASTM and BS
Standard delivery scope
- Main unit TIME®2600
- Probe (F1 or N1)
- Substrate
- Calibration foil
- Charger
- Printing paper
- Instruction manual
Special accessories
- Additional probes for special applications
Downloads
Data sheet (PDF)
pdf - 254 KB
Specifications
| Parameter | TIME®2600 |
| Measuring principle | Magnetic induction (F) and eddy current (N), depending on probe |
| Measuring range | Standard probes F1 / N1: 0 – 1250 µm; further probes see probe table |
| Resolution | 0.1 µm (CN02: 1 µm) |
| Accuracy, one-point calibration | F: ±(3 % H + 1) µm; N: ±(3 % H + 1.5) µm (H = reading) |
| Accuracy, two-point calibration | F: ±[(1–3) % H + 1] µm; N: ±[(1–3) % H + 1.5] µm |
| Standards | DIN, ISO, ASTM, BS |
| Calibration | Zero and foil calibration |
| Working modes / measuring ways | DIRECT, BATCH / CONTINUE, SINGLE |
| Statistics | Number of readings, mean, standard deviation, maximum, minimum |
| Memory | 640 readings |
| Limits | Adjustable, with alarm |
| Interface | RS232 |
| Printer | Integrated printer |
| Power supply | NiMH rechargeable battery |
| Operating environment | 0 – 40 °C, 20 – 90 % RH, no strong magnetic field |
| Dimensions | 230 × 86 × 47 mm |

| Probe | Principle | Range (µm) | Accuracy one-point (µm) | Accuracy two-point (µm) | Resolution (µm) | Min. curvature radius (mm) | Min. area (mm) | Critical substrate thickness (mm) |
| F400 | Magnetic induction | 0 – 400 | ±(3 % H + 1) | ±[(1–3) % H + 0.7] | 0.1 | convex 1 | Ø 3 | 0.2 |
| F1 | Magnetic induction | 0 – 1250 | ±(3 % H + 1) | ±[(1–3) % H + 1] | 0.1 | convex 1.5 | Ø 7 | 0.5 |
| F1/90° | Magnetic induction | 0 – 1250 | ±(3 % H + 1) | ±[(1–3) % H + 1] | 0.1 | convex 1.5 | Ø 7 | 0.5 |
| F10 | Magnetic induction | 0 – 10000 | – | – | – | 10 | Ø 40 | 2 |
| N1 | Eddy current | 0 – 1250 0 – 40 (chrome on copper) | ±(3 % H + 1.5) | ±[(1–3) % H + 1.5] | 0.1 | convex 3 | Ø 5 | 0.3 |
| CN02 | Eddy current | 10 – 200 | ±(3 % H + 1) | – | 1 | flat | Ø 7 | unlimited |
Probe selection guide
| Substrate / Coating | Non-magnetic coatings (organic materials like paint, enamel, plastic) | Non-magnetic metal coatings (chromium, zinc, copper, tin, silver, etc.) | |||
| Coating thickness less than 100 µm | Coating thickness more than 100 µm | Coating thickness less than 100 µm | Coating thickness more than 100 µm | ||
| Steel, iron and other magnetic metals | Diameter of testing area more than 30 mm | F1: 0 – 1250 µm F400: 0 – 400 µm | F1: 0 – 1250 µm F10: 0 – 10 mm | F1: 0 – 1250 µm F400: 0 – 400 µm | F1: 0 – 1250 µm F10: 0 – 10 mm |
| Diameter of testing area less than 30 mm | F400: 0 – 400 µm | F1: 0 – 1250 µm F400: 0 – 400 µm | F400: 0 – 400 µm | F1: 0 – 1250 µm F400: 0 – 400 µm | |
| Copper, brass, aluminum, zinc, tin and other metals | Diameter of testing area more than 5 mm | N1: 0 – 1250 µm | N1: 0 – 40 µm (for chrome plate on copper only) | ||
| Non-metallic substrate | Diameter of testing area more than 7 mm | – | – | CN02: 10 – 200 µm (mainly for testing copper foil) | |
Areas of application of the TIME®2600
- In paint shops
- For powder and paint coatings
- For automotive appraisers and automotive insurance companies
- In the automotive industry
- In workshops
- In quality control
- In bridge construction
- In shipbuilding
- In goods receivingIn the manufacturing process
- In the laboratory


















![[Translate to English:] Härteprüfgerät TIME®5350 Hardness tester TIME®5350](/fileadmin/_processed_/6/3/csm_haertepruefgeraet-time5350_bbfdaba37b.webp)
![[Translate to English:] Hardness tester TIME®5630](/fileadmin/_processed_/d/4/csm_haertepruefgeraet-time5630_1d90ea6e04.webp)

![[Translate to English:] Hardness tester Shore Durometer](/fileadmin/_processed_/5/7/csm_haertepruefgeraet-shore-durometer_cf6f60ff1c.webp)









![[Translate to English:] Roughness tester TIME®3100](/fileadmin/_processed_/5/1/csm_time3100_4982bd6c41.webp)

![[Translate to English:] Roughness tester TR110/TIME®3110](/fileadmin/_processed_/9/1/csm_rauheitsmessgeraet-tr-110-time-3110_f187168273.webp)
![[Translate to English:] Roughness tester TR200/TIME®3200 and TR220/TIME®3202](/fileadmin/_processed_/2/5/csm_rauheitsmessgeraet-tr200-time3200-tr220-time3202_7e08574567.webp)


![[Translate to English:] Gloss meter GlossTector 60° / 20°60°85°](/fileadmin/_processed_/2/1/csm_glanzmessgeraet-glosstector_30b19a3b3a.webp)

![[Translate to English:] Gloss meter GlossTector 60° Plus](/fileadmin/_processed_/b/8/csm_glosstector-60-plus_b8fb4adc49.webp)
![[Translate to English:] Gloss meter GlossTector 20°60°85° Plus](/fileadmin/_processed_/6/2/csm_drei-winkel-glosstector-plus_a70ce00c1a.webp)

![[Translate to English:] SaluTron Vibro 200](/fileadmin/_processed_/f/1/csm_salutron-vibro-200_eda5baa52b.webp)
![[Translate to English:] SaluTron Vibro 260](/fileadmin/_processed_/5/3/csm_salutron-vibro-260_014d26f682.webp)