TIME®2130/2132/2134: Ultrasonic wall thickness gauges for steel, high temperatures and cast iron
TIME®2130/2132/2134
The TIME®2130, TIME®2132 and TIME®2134 from Beijing Time High Technology Ltd. are digital ultrasonic wall thickness gauges for non-destructive wall thickness measurement on metal components. All three models feature an RS232 interface for connecting the TA230 printer and a PC (software optional).
The TIME®2130 works with the standard probe 5PΦ10/90°, the TIME®2132 is designed with probe ZW5P for measurements on hot surfaces up to 300 °C, and the TIME®2134 comes with probe TSTU32 for cast iron.
Properties of the TIME®2130/2132/2134
- RS232 interface for connecting the TA230 printer and a PC with optional software
- TIME®2132: high-temperature resistant up to 300 °C
- TIME®2134: equipped with probe TSTU32 for cast iron
- Free conversion between metric and imperial units
- Automatic zero-point calibration: automatically corrects system errors
- Gain adjustment, low-battery indication and automatic switch-off
- Memory for 500 readings and 5 sound velocities (store, delete, review)
- Large LCD with backlight and adjustable contrast
- Two display modes: current thickness or minimum thickness
- Two-point calibration for high accuracy
- Presettable upper/lower limits with audible alarm
- Resolution 0.01 mm and 0.1 mm selectable
Applications of the TIME®2130/2132/2134
By using wall thickness gauges, materials that are exposed to corrosion or erosion can be monitored, ensuring the safe use of, for example, a pressure vessel.

Standard delivery scope
- Main unit
- Probe 5PΦ10/90° (TIME®2130)
- Probe ZW5P (TIME®2132)
- Probe TSTU32 (TIME®2134)
- Couplant
- Sheath for main unit
- Operating manual
Special accessories
- Additional probes
- Printer TA230 with cable
- Dataview software
Downloads
Data sheet TIME®2130/2132/2134 (PDF)
pdf - 172 KB
Specifications
| Parameter | TIME®2130 | TIME®2132 | TIME®2134 |
|---|---|---|---|
| Measuring range | 0.75 – 300.00 mm (steel), depending on probe | 1.2 – 225.0 mm (steel) 5.0 – 80.0 mm (steel, high temperature) | 1.2 – 300.00 mm 5.0 – 40.0 mm (cast iron) |
| Measuring accuracy | ±(1 % H + 0.1) mm (H = thickness of test piece) | ||
| Lower limit for steel pipes | Ø 20 mm × 3.0 mm | ||
| Display resolution | 0.1 mm / 0.01 mm | 0.1 mm | 0.1 mm |
| Sound velocity | 1,000 – 9,999 m/s | ||
| Power supply | 2 × AA batteries, 1.5 V | ||
| Battery life | 100 hours (without backlight) | ||
| Units | mm / inch | ||
| Operating temperature | -10 – +60 °C | -10 – +300 °C | -10 – +60 °C |
| Dimensions | 152 × 74 × 35 mm | ||
| Weight | 370 g | ||
Velocities at different materials
| Material | V (in/µs) | V (m/s) |
|---|---|---|
| Aluminium; gewalzt | 0,2530 | 6420 |
| Aluminium; 6061-T6 | 0,2510 | 6383 |
| Beryllium | 0,5073 | 12890 |
| Messing, 70 CU, 30 Zn | 0,1850 | 4700 |
| Kupfer; gewalzt | 0,1972 | 5010 |
| Duraluminium | 0,2487 | 6320 |
| Eisen | 0,2345 | 5960 |
| Blei; gewalzt | 0,0771 | 1960 |
| Magnesium; gezogen/geglüht | 0,2270 | 5770 |
| Molybdän | 0,2470 | 6250 |
| Monel | 0,2105 | 5350 |
| Nickel | 0,2377 | 6040 |
| Stahl; normal | 0,2331 | 5920 |
| Stahl; leicht legiert | 0,2259 | 5734 |
| Nichtrost. Stahl | 0,2278 | 5790 |
| Titan | 0,2402 | 6100 |
| Wolfram, gezogen | 0,2129 | 5410 |
| Uran | 0,1330 | 3370 |
| Zink; gewalzt | 0,1657 | 4210 |
| Zink; gespritzt | 0,1756 | 4460 |
| Aluminium, AL203 99,5% | 0,4013 | 10190 |
| Quarzglas | 0,2349 | 5968 |
| Geschmolzen | 0,2335 | 5932 |
| Pyrex Glas | 0,2220 | 5640 |
| Lucite | 0,1055 | 2680 |
| Plexiglas | 0,1077 | 2735 |
| Nylon | 0,1031 | 2620 |
| Polyethylene | 0,0705 | 1950 |
| Polystyrole | 0,0925 | 2350 |
| Silicon-Gummi | 0,0373 | 948 |
| Wasser | 0,0590 | 1490 |
Overview of compatible transducers for the ultrasonic wall thickness gauges TIME®2130/2132/2134
| Transducer type | Standard delivery with | Measuring range | Remarks |
|---|---|---|---|
| 5PΦ10/90° | TIME®2130 | 0.75 – 300.00 mm (steel), depending on probe | Standard probe for general applications |
| ZW5P | TIME®2132 | 5.0 – 80.0 mm (steel, high temperature) | High-temperature probe up to 300 °C |
| TSTU32 | TIME®2134 | 5.0 – 40.0 mm (cast iron) | Probe for cast iron |
Areas of application of the TIME®2130/2132/2134
- Steel plates
- Sheet metal
- Finishing parts
- Pipes
- Pressure vessels
- For example in the petroleum, chemical, metal, ship, space, and aerospace industries















![[Translate to English:] Härteprüfgerät TIME®5350 Hardness tester TIME®5350](/fileadmin/_processed_/6/3/csm_haertepruefgeraet-time5350_bbfdaba37b.webp)
![[Translate to English:] Hardness tester TIME®5630](/fileadmin/_processed_/d/4/csm_haertepruefgeraet-time5630_1d90ea6e04.webp)
![[Translate to English:] Hardness tester Shore Durometer](/fileadmin/_processed_/5/7/csm_haertepruefgeraet-shore-durometer_cf6f60ff1c.webp)









![[Translate to English:] Roughness tester TIME®3100](/fileadmin/_processed_/5/1/csm_time3100_4982bd6c41.webp)

![[Translate to English:] Roughness tester TR110/TIME®3110](/fileadmin/_processed_/9/1/csm_rauheitsmessgeraet-tr-110-time-3110_f187168273.webp)
![[Translate to English:] Roughness tester TR200/TIME®3200 and TR220/TIME®3202](/fileadmin/_processed_/2/5/csm_rauheitsmessgeraet-tr200-time3200-tr220-time3202_7e08574567.webp)


![[Translate to English:] Gloss meter GlossTector 60° / 20°60°85°](/fileadmin/_processed_/2/1/csm_glanzmessgeraet-glosstector_30b19a3b3a.webp)

![[Translate to English:] Gloss meter GlossTector 20°60°85° Plus](/fileadmin/_processed_/6/2/csm_drei-winkel-glosstector-plus_a70ce00c1a.webp)

![[Translate to English:] SaluTron Vibro 200](/fileadmin/_processed_/f/1/csm_salutron-vibro-200_eda5baa52b.webp)
![[Translate to English:] SaluTron Vibro 260](/fileadmin/_processed_/5/3/csm_salutron-vibro-260_014d26f682.webp)